I'm curious to see what it looks like when displaying a waveform. I'll go look at circuit diagrams and see if I can get a sense of what these do.ĭo you have an oscilloscope probe? If so, could you (1) plug the probe into the ChA input and then (2) hook the probe to the calibration pin on the front panel and (3) film the waveform and show what happens when you move the position knob and then post it to youtube for me to look at? The other thing common to both channels is the block labeled "Mode Control Logic / Vertical Select / Trigger Select" - I'm not 100% sure what these do, but the problem could lie there as well. This seems like an electronics problem, not a CRT problem. There's two obvious things common to both CHA and CHB, all coupling - the CRT itself and the vertical amplifier (the "Output" triangle below). Here's the block diagram from the service manual. That helps because it eliminates a bunch of blocks from the 'suspect' list. So whatever the problem is, it's common to both channels and all the coupling. Third, when you set Channel B coupling to AC and adjust the position knob, what happens? What about when you set coupling to DC? Second, when you set Channel A coupling to AC and adjust the position knob, what happens? What about when you set coupling to DC? I am kind of winging it here.įirst off, does this behavior only happen on channel A? Or does this also happen on channel B? Let's see if we can isolate down to the block, circuit and then component levels.
PROTEK 506 SERVICE MANUAL PDF
In the PDF take a look at the chapter called "Troubleshooting the Vertical Section" So maybe that has something to do with it. The vertical position adjust is part of the vertical section circuitry. You seem to be having a problem getting the beam to show up below a certain point on the screen. It also is responsible for triggering when to sweep, blanking the beam when sweeping right to left to start another sweep. The horizontal section is what sweeps the beam from left to right. At present I'd put my money on a problem with the vertical section. The vertical section controls the position of the beam on the vertical axis. The power supply of course provides various voltage to all the other sections. The o-scope is made up of several main sections. So, step one, diagnose the faulty section. Their approach is-diagnose from the front panel. Take a look at that PDF and just kind of skim through it and get the gist. I couldn't make out the settings but that is ok. Service manuals, schematics, eproms for electrical technicians.Cool thanks.
PROTEK 506 SERVICE MANUAL MANUAL
Try Prime Automotive Parts & Accessories Go Search EN Hello Download PROTEK HUNG CHANG 506 DMM SCH service manual & repair info for electronics experts.
PROTEK 506 SERVICE MANUAL FREE
Buy Protek D981 Multimeter: Multimeters & Analyzers - FREE DELIVERY possible on eligible purchases. Electronics service manual exchange : schematics,datasheets,diagrams,repairs,schema,service manuals,eeprom bins,pcb as well as service mode entry, make to model and chassis correspondence and more. Prism Electronics will pay for return shipping costs. All returns must include all original undamaged items, in resalable condition with all original packaging including manuals, warranty forms, etc. User manual PROTEK 3201 Strength Analyzer - Download PDF file This document contains important information to use and/or repair your appliance. As youre Protek 3201 Service Manual to infer from its name, Doc to Image Converter transforms Microsoft Word files into Protek 3201 Service Manual image formats. PROTEK 506 - Calibration Services Calibrate your instrument with Tektronix Multi-Brand Calibration Services Tektronix offers accredited calibration services for more than 140,000 instruments from 9,000 manufacturers. Protek Digital Multimeter D-945 Manual Ranging 4-Digit. PROTEK 506 DIGITAL MULTIMETER TRUE RMS RS232C INTERFACE. Filter (1) Protek Test Equipment Multimeters. Protek Test Equipment Multimeters Skip to page navigation. With over 25 years of engineering and manufacturing experience, we offer application specific solutions for all electronic equipment/systems. FEATURES l True RMS Mode l Dual Display for Frequency AC Voltage and Temperature l RS232C Interface l 10 Location Memory l Time Mode with Alarm Clock and Stop Watch l MIN.
PROTEK 506 SERVICE MANUAL FULL
ProTek Devices is a leading semiconductor manufacturer of a wide range of high-performance TVS protection, analog and mixed-signal products. DIGITAL MULTIMETER Protek 506 3 3/4Digit, 4000 count auto-ranging with analog bar graph, 9,999 (10MHz) count frequency count and full enunciators.